Load Area: 72” diameter x 72” high
Chamber Size: 96” diameter x 108” high
Heating Elements: Molybdenum
Controls:
• Temperature Instrument: HW UDC-2000 Overtemp
• Vacuum Instrument: Granville Phillips 307; Yokogowa Digital Recorder
• Programmer: HW DCP-550
Maximum Temp: 2400°F
Roughing Pump: 300 CFM
Vacuum Booster: 1600 CFM
Diffusion Pump: 47,000 L/S
Part. Pressure: Argon or Nitrogen
Pos. Pressure: 15 PSI (2 Bar)
Gas Cooling: 9,000 CFM
Backfill Gas: Argon or Nitrogen
Electrical:
• Source Voltage: 460V / 3-Phase / 60Hz
• Motor & Control Load: 212Amps fused @ 300 Amps
• Hot Zone Load: 847 Amps
• Total Connected Load: 917 Amps
Water
• Peak Demand: 288 GPM
• Pressure & Temp: 40 to 70 PSIG @ 85°F
• Inlet Connection: 3” FPT
• Drain: 4” FPT
Inert Gas:
• Pressure: 100 PSIG max
• Connection: 1-1/2” nominal
• SCF/Backfill: 575
Air:
Pressure: 90-100 PSIG
Maxiumum Connection: 1/4 nominal
SCFM/F/R/L: 1.5